1 Introduction to SupaPurlin SupaPurlin is a computer program for the analysis and design of SupaCee purlins. The sections can be designed with or without roof sheeting attached.

sydney.edu.au

AISI PUBLISHES DESIGN GUIDE FOR COLD-FORMED STEEL PURLIN ROOF ...

Microsoft Word - AISI Publishes Design Guide for Cold-Formed Steel Purlin Roof Framing System.doc

www.mbma.com

Fig.5.19 Z Purlins

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. ... • Purlin cleats should provide adequate torsional restraint. 5.9.2 Design rules The following design rules apply with reference to Fig. 5.19 • The overall depth should be greater than 100 t and not less than L /45.

nptel.iitm.ac.in

Selected Loadings

May 2004 Purlin Systems 2.4.8 DESIGN EXAMPLE - TOP NOTCH PURLINS Selected Loadings Dead Load, G = 0.12 kPa Live Load, Q = 0.25 kPa Snow Load, S u = 0.5 kPa Outward Limit State Wind Loads, W u = -0.95 kPa (ultimate state) and W s = -0.66 kPa (serviceability state).

www.productspec.net

Connection Design Manual – Part 7: Purlin Cleats

LiteSteel Technologies ACN 113 101 054. PO Box 246 Sunnybank, Queensland 4109 Australia Telephone +61 1300 789 572 Facsimile +61 1300 789 368 E-mail lsb@litesteelbeam.com.au Internet www.litesteelbeam.com.au See page (ii) for the appropriate use of this publication.

www.litesteelbeam.com.au

NUMERICAL ANALYSIS OF COLD-FORMED STEEL PURLIN-SHEETING SYSTEMS

In addition to verifying failures (plastic moment and instabilities), the design of purlin-sheeting systems should include a careful evaluation of the service moment capacity corresponding to excessive displacements, ...

www.ce.jhu.edu

Building Constraints

May 2004 Purlin Systems 2.3.11 DESIGN EXAMPLES 2.3.11.1 EXAMPLE: PURLINS, SINGLE AND LAPPED Loadings Dead Load, G = 0.12 kPa Live Load, Q = 0.25 kPa Snow Load, S u = 0.50 kPa Outward Limit State Wind Loads, W u = -0.95 kPa and W s = -0.66 kPa Inward Wind Loading is not signifi cant for this roof.

www.productspec.net

Rafter & Purlin Truss Detailing

Detailing Posi-STRUT™ 30 Rafter & Purlin Truss Detailing Rafter End Details There is a large number of possible details for the ends of rafter trusses depending on style of eaves and fixing requirements. ... Otherwise specific design will be required.

www.mii.com

Cold-formed steel design

Purlin design For the cross-sections that meet all requirements of Chapter 10, the reduced default checks are executed. This means that not all default checks will be executed and that the special purlin checks according to Chapter 10 will be performed ...