 Heavy or special purpose lighting can fail at the ...

For suspended acoustic ceilings in Seismic Design Category D, E & F, ASTM E580 requires that the ceiling surrounding such a fixture must be detailed as if it were a perimeter closure that must allow the required clearances by use of suitable closure details; ...

www.fema.gov

SECTION 09 51 00 ACOUSTICAL CEILINGS

Construct system in accordance with ASTM E580. 2.

www.vendorportal.ecms.va.gov

SECTION 09510 SUSPENDED ACOUSTICAL CEILING SYSTEM

ASTM C636 - Standard Practice for the Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels C. ASTM C665 - Standard Specification for Mineral Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing D. ASTM E580 ...

facilities.fit.edu

Codes and Installation Standards

For more information call 1 877 ARMSTRONG 2-42 Drywall & ShortSpan Grid Systems Trapeze Loading per ASTM C 636 Members Gauge 0 ′ - 4 ...

www.armstrong.com

DOCUMENT

astm el 19-09 astm e580/e580m-09a astm e2030-09a astm e2073-09 astm e2326-09 astm e2413-04 (r09) astm e2631-09 astm f1488-09 astm f16'75-09 astm f2788-09 jesd8-22 j9sil22-b101 b tia 568-c.2c ansi c136.38-09 iso/iec 23000-4 amd zed2 standard test methods for fire tests of 3uilding construction and materials ...

standardsport.com

ORDER FOR SUPPLIES OR SERVICES*

Apply Seismic requirements for acoustical ceiling suspension systems as required by ASTM E580. Coordinate with Structural requirements. 6. Are any fire protection systems required for the GSE shop?

www.neco.navy.mil

Suspended Ceiling Checklist

References are to the 2006 International Building Code (IBC), ASCE 7-02, ASTM C 636-04, and CISCA Guidelines for seismic zones 3-4. Please verify the following before calling for the ceiling grid inspection.

www.desmoinesmail.com

Installation of Ceiling Suspension Systems for Acoustical ...

FIG. 1 Category C Treatment of Cross Runners, Main Runners, and Wall Closures at Terminal Ends E580/E 580M-09a 2 Copyright by ASTM Int'l (all rights reserved); ...

www.bcceilings.com

Regional Military Training Center

... -row mounted fixtures shall be supported by a seismic-resistant suspended ceiling support system built in accordance with ASTM E580. Seismic protection for the fixtures shall ...

www.aed.usace.army.mil

ACOUSTICAL TILE AND LAY-IN PANEL CEILING SUSPENSION SYSTEMS

section bc r103 modifications to astm c 636 - standard practice for installation of metal ceiling suspension systems for acoustical tile and lay-in panels r103.1 astmc636, section 2.1.3.

www2.iccsafe.org